Additional Troubleshooting for WAP-7 Locomotives Working with HOG
13 Sep 2026South Eastern Railway
Office of the Pr. Chief Electrical Engineer
41, Garden Reach, Kolkata-43
No. PCEE/RS/268/Misc./26/105 | Date: As signed
⚠️ Additional Troubleshooting for WAP-7 Locomotives Working with HOG
Ref.: OPR of Loco No. 39224/WAP-7/SRCE dated 01.09.2026
Issued to: Sr. DEE/OP/KGP, CKP, ADRA & RNC
WAP-7 locomotives working in HOG mode with power cars have experienced failures due to tripping of the following control circuit MCBs:
In many cases, the following indications have been logged despite MR pressure being available and within normal limits:
Recommended Action
- In the event of the above failures, disconnect the HOG UIC coupler once.
- Re-check the locomotive after disconnecting the HOG UIC coupler.
- Check whether the reported trouble recurs.
MCB 127.7 in the SB-2 panel was found tripped and could not initially be reset. After battery OFF/ON, MCB 127.7 reset, but tripped again when the battery was switched ON.
F1001P1 – “Brake Electronics Failed, Emergency Brakes Applied and No Traction Allowed”
- MCB 127.7 and MCB 129.2/1-1 (HOG) were found in tripped condition.
- Pneumatic testing of both cabs was found normal after making MCB 127.7 normal.
- An earth fault in the battery circuit was logged when the locomotive was made live.
- HLC2 lamp glowing without jig indicated a positive earth fault in the locomotive.
- Positive cables 16B and 57A in the pneumatic panel were found pressed and punctured at the snubber circuit PCB board.
- Cab-1 LP-side HOG IV coupler cap short link plate for pin numbers 7 & 10 was found earthed, causing positive earth fault of HOG.
- Cab-2 LP IV coupler cables were found pressed with insulation damage, causing positive earth fault of HOG.
| Fault Code | Fault Description |
|---|---|
| F0905P2 | MCC: Earth Fault in Battery Circuit |
| F1005P1 | MCC: S/R Interlock – Auto Brake |
| F1002P1 | MCC: S/R Interlock – Main Res Low |
| F0103P1 | MCC: Low Panto Pressure – VCB Off |
| F1001P1 | MCC: Brake Electronics Failed |
| F0103P1 | MCC: No Pressure in Panto 2 |
| F0106P2 | MCC: AFL Activated |
Joint checking was carried out at VSKP with Loco No. 37200/BZA and Power Car No. 138853.
The loco display showed an earth fault, which disappeared after removing the UIC.
- Complete implementation of RDSO MS-488, Rev.1 dated 12.03.2026 in all HOG locomotives.
- Carry out one-cycle checking of all cables and connectors of the E70 brake system.
Chief Electrical Loco Engineer
South Eastern Railway